The Bei Ermei has been designed for fast automatic testing of newborn babies, chil
MSOAE-1H | Climatic conditions | Ambient temperature 10' -40' | Adopt high performance, low energy AVR microprocessor, equipped with TEOAE and DPOAE | |
Relative Humidity: NMT 85% | Particular noise-cancelling function, real-time display of waveform and data in the testing procedure | |||
Barometric Pressure: 700hPa-1060hPa | USB interface can be directly connected to the computer for data sharing, which can support long-distance medical treatment | |||
Power Supply Voltage | AC 220v± 22v 50± 1Hz | The probe head conforms to the human engineering, the outer covering and sound track tube can be easily dismantle and clean, to prevent cross infection; | ||
DC 5v± 0.3v | Probe self-checking function can display waveform, in order to judge coupling situation, increase the testing accuracy | |||
Input Power | ≤ 10w | Adopt serial port communication technology, can print the detailed test result | ||
Output Sound Pressure Extent | Click stimulus output | Stimulation sound range: 50dB-80dBspl, adjustable level, 5dBspl per level. Error range: actual output and display value≤ ± 2dBspl | It can run in the windows Xp, and also adopt universal data format for the resource sharing and telecommunications network. | |
Pure-tune stimulus output | Stimulation sound range: 60dB-80dBspl, adjustable level, 5dBspl per level. Error range: actual output and display value≤ ± 2dBspl | User-friendly interface design, graphical display, and also display single or double ears’ testing data and waveform; | ||
sound acceptable pressure | 0dB-80dBspl, adopting pure-tone stimulation as signal importing, the error range(between display value of the detector and output value)≤ ± 3dBspl | Easy to input hospital’ s name, patient’ s name, sex, age, clinical feature and doctor' s decision. | ||
Noise-cancelling range | 35dB-50dBspl, adjustable level, 5dBspl per level | It can store over 2 million pieces of case information |
Audiometer, Otoacoustic Emission Detector, Oae, Hearing Screen